Slipstream Measurements
The following measurements were performed outdoor with the speaker on the ground pointing upwards to simulate on wall 2pi mounting.
A quick set of 4pi off axis measurements here.
Measurements were taken at 2.83v / 1M on the tweeter axis.
Measurements are gated at 55ms, smoothing applied is 1/24th octave.
On Axis Response
CTA-2034 Style Spin
Estimated In-Room Response
Harmonic Distortion - 85, 95, 100 & 105dB / 1m
Compression - 85, 95, 100 & 105dB / 1m